| QUALITY OPEN & SILENT PERKINS GAS, BIOGAS& SYNGAS GENERATORS & CHP UNITS |
22kVA - 365kVA Quantum Range |
|||
|
Engine Range
|
Model
|
Prime (PRP) Rating kVA
|
Control Panel Type
|
| Q3.3si |
22
|
20
|
DeepSea
|
| Q3.3si |
33
|
30
|
DeepSea
|
| Q3.3si |
44
|
40
|
DeepSea
|
| Q4.4si |
66
|
60
|
DeepSea
|
| Q6.6si |
88
|
80
|
DeepSea
|
| Q6.6si |
110
|
100
|
DeepSea
|
| Q6.6tasi |
130
|
120
|
DeepSea
|
| Q6.15tsi |
165
|
150
|
DeepSea
|
| Q6.18tsi |
220
|
200
|
DeepSea
|
| Q6.18tsi |
275
|
250
|
DeepSea
|
| Q6.18tasi |
300
|
275
|
DeepSea
|
| Q6.18tasi |
400
|
365
|
DeepSea
|
376kVA - 1000kVA Perkins 4000 Range |
|
|
Engine Range
|
Model
|
| 4006 23 TRS 2 | |
| 4006 23 TRS 2 | |
| 4008 30 TRS 1 | |
| 4008 30 TRS 2 | |
| 4012 TESI LC200 | |
| 4016 TESI LC200 | |
| 4016 E61 TRS |
BSGG 1250
|
The machines are all mounted in containers (ISO frame size) with radiators mounted internally.
Standard Scope of Supply of CHP units
The machines specified below are designed and built with cooling
by heat exchanger on the set to provide external heating.
The proposals are all based on the widely respected Perkins engines range. These
engines are well established and there is excellent support in the country.
During 2008, the complete range of Perkins gas engines is due for release in uprated
format. The original "4000 series" derivation remains the same, but with new subscript
descriptions. Where the uprated version is already released, proposals have been
based upon them. Where not yet released, the original derivation is still used.
It is possible that during the period between this submission and any order, the
latest engine version may become available. This may affect both performance figure
and price.
The machines are all mounted in containers (ISO frame size) with
radiators mounted internally.
| Engine fitted with: |
Carburettor and gas train suitable for gas pressure 20 to 50 mbar. Starter motor and 24v battery charging system Electronic ignition Electronic governor Thermostats on engine jacket and intercooler Jacket and intercooler water pumps Air filter HWT and LOP shutdown switches Silencing system in mild steel Anti-vibration mountings 24 volts batteries |
||||||||||
| Heat recovery |
Exhaust heat recovery units Jacket/secondary cooling water heat exchanger Heat dump system - electrically driven fan cooled radiators |
||||||||||
| Alternator fitted with: | Single bearing with rigid connection to engine | ||||||||||
| Automatic voltage regulator | |||||||||||
| Control panel suitable for key start. PLC based control system | |||||||||||
| Alternator mounted circuit breaker. | |||||||||||
Shutdown functions:
|
|||||||||||
| Engine is fitted with automatic oil make-up system and separate oil storage tank. An on-board pump is also fitted for oil draining. | |||||||||||
| Engine/alternator assembly is mounted to a substantial steel bedplate with anti-vibration mounts designed for 90% isolation. | |||||||||||
| Exhaust systems are constructed of mild steel. | |||||||||||
| Engine is fitted with fuel system in accordance with regulations, with duplicated valves, filter, pressure regulator, mixture adjustment and carburettor. | |||||||||||
| All equipment mounted in an ISO frame container for simple transport. Service tappings at the container wall and/or roof. | |||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||