QUALITY OPEN & SILENT
PERKINS GENERATORS
UNBEATABLE PRICES
Contact us

 

PERKINS/NEWAGE PRICE LIST

British Made Generators using Perkins Engines coupled to Newage Alternators.

New Generators - British Made New Generators - Perkins New Generators - Newage UCC
Click here to open the
XE.com Currency Converter
50Hz @ 1500 RPM (400 / 230 volt)
Prices in Sterling Pounds  (GBP)
KVA ENG TYPE OPEN SETS Additional Cost for Fuel
Consumption
Litre/Hr
Manual
Start
Auto
Start
ATS
Panel
Acoustic
Enclosure
CE
CERT
(EU Only)
8 403C-11G

3497

3901

290

1530

120

2.2
12 403C-15G

3898

4307

290

1530

120

3.3
20 404C-22G

4400

4810

308

1530

120

5.5
30 1103A-33G

5164

5561

365

1778

120

8.3
40 1103A-33TG1

5680

6078

386

1927

120

11.9
45 1103A-33TG1

5861

6298

407

1927

120

13.4
60 1104A-33TG2

6486

6950

449

1927

120

14.8
65 1104A-44TG1

6752

7217

473

2282

120

16.3
80 1104C-44TAG1

7738

8207

640

2282

120

19
85 1006TG1A

7970

8476

640

2282

120

21
100 1104C-44TAG2

8605

9110

786

2282

168

23.8
138 1006TAG

11090

11639

810

3352

168

32
150 1006TAG2

12433

12982

810

3352

168

32
180 1006C-E66TAG4

14429

14834

1012

4440

168

42
200 1306C-E87TAG3

16198

16600

1111

4440

168

42.7
225 1306C-E87TAG4

17371

17753

1402

4440

168

47
250 1306C-E87TAG6

17512

17946

1510

4375

168

53.5
300 2306A-E14TAG2

21478

21952

1667

6169

202

56.7
350 2306A-E14TAG2

22163

22717

1782

6169

202

58.2
400 2306A-E14TAG3

24642

25196

2017

7664

202

89
450 2506A-E15TAG1

29363

30070

2359

7601

202

90.5
500 2506A-E15TAG2

31931

32645

3498

7601

202

102
600 2806A-E18TAG1A

39823

40332

3498

9371

265

121
650 2806A-E18TAG2

43429

43854

4650

9371

265

130
730 4006C-23TAG2A

58880

57842

5147

18436

324

145
800 4006C-23TAG3A

60913

59875

5147

18436

324

159
850 4008-TAG

80546

77876

7024

29257

324

165
900 4008-TAG1A

80863

78193

7024

29257

324

170
1000 4008-TAG2A

83749

81079

7024

29257

324

215
1250 4012-46TWG2A

118266

114224

8515

35520

324

264
1360 4012-46TWG3A

127202

122251

8515

35520

324

291
1500 4012-46TAG2A

133708

128755

10606

35520

324

305
1700 4012-46TAG3A

148140

141822

13760

-

324

350
1840 4016TAG1A

196024

189706

13760

-

392

390
2000 4016TAG2A

207744

201426

13760

-

392

422
27°C (80°f) 152M (500ft) @ 60% relative humidity
All prices are in Sterling Pounds GBP Ex works UK
Prices are subject to VAT @17.5% (where applicable)
Sales are subject to our terms and conditions click here to view

 

 

PERKINS/MECCALTE PRICE LIST

British Made Generators using Perkins Engines coupled to Meccalte Alternators.

New Generators - British Made New Generators - Perkins New Generators - Meccalte UCC
Click here to open the
XE.com Currency Converter
50Hz @ 1500 RPM (400 / 230 volt)
Prices in Sterling Pounds  (GBP)
KVA ENG TYPE OPEN SETS Additional Cost for Fuel
Consumption
Litre/Hr
Manual
Start
Auto
Start
ATS
Panel
Acoustic
Enclosure
CE
CERT
(EU Only)
9 403C-11G

3323

3727

290

1530

120

2.2
13 403C-15G

3762

4171

290

1530

120

3.3
20 404C-22G

4199

461

308

1530

120

5.5
30 1103A-33G

4945

5342

365

1778

120

8.3
40 1103A-33TG1

5413

5810

386

1927

120

11.9
45 1103A-33TG1

5582

6019

407

1927

120

13.4
60 1104A-33TG2

6235

6700

449

1927

120

14.8
65 1104A-44TG1

6437

6901

473

2282

120

16.3
80 1104C-44TAG1

7469

7939

640

2282

120

19
85 1006TG1A

7702

8207

640

2282

120

21
100 1104C-44TAG2

8250

8758

786

2282

168

23.8
140 1006TAG

1063

11179

810

3352

168

32
150 1006TAG2

11389

11936

810

3352

168

32
180 1106C-E66TAG4

13436

13843

1012

4440

168

42
200 1306C-E87TAG3

14996

15397

1111

4440

168

42.7
225 1306C-E87TAG4

16172

16554

1402

4440

168

47
250 1306C-E87TAG6

16428

16862

1510

4375

168

53.3
27°C (80°f) 152M (500ft) @ 60% relative humidity
All prices are in Sterling Pounds GBP Ex works UK
Prices are subject to VAT @17.5% (where applicable)
Sales are subject to our terms and conditions click here to view

 

 

Standard Tempest Specification

Perkins 400, 1000 & 1100 Range ( 8 to 200 KVA )

New Generators - British Made New Generators - Perkins
Generating Set
New Generator Open Set with Perkins Engine
  • Set Mounted Tropical Duty Radiator
  • Engine Driven Cooling Fan with Protection Guard
  • Radiator Stone Guard
  • Fuel, Lubricating Oil and Air Filter with Restriction Indicator
  • Mechanical governing at 1500/1800 RPM in accordance with BS5514A1 (1)
  • 12 Volt electric start with charging alternator
  • Protection Switches for
    • High Engine Temprature
    • Low oil pressure
  • Wiring to Control Panel
  • Steel base frame with integral 8 hour capacity fuel tank, complete with contents gauge, steel wire braded fuel lines, fill, vent and drain fittings
  • Anti vibration mountings fitted between the engine/alternator feet and base
  • Set mounted Yuasa maintenance free lead acid battery with leads and terminals
  • Exhaust flexible section with connections
  • S.L.S. Silencer supplied loose
  • Load and function tests
  • Paint finish to our standard scheme
  • Comprehensive user manual
Keystart

Alternator mounted profile control panel comprising -

  • Ammeter per phase
  • 1 x voltmeter
  • Voltmeter selector switch (2)
  • Dual scale frequency/RPM indicator
  • Hour counter
  • 3 pole MCB/MCCB Mounted in control panel (2),(3)
  • Deep Sea 701 keystart module
  • Shutdown indicator for
    • High Engine Temperature
    • Low oil pressure
    • Overspeed
  • Oil Pressure Gauge
  • Water temperature gauge
  • Battery voltmeter
Autostart

As keystart but comprising the following additions -

New Generator Acoustic (Canopied) Set with Perkins Engine

  • Constant Potential barrety charger
  • Battery charger On/Off pushbutton
  • Deep Sea 521K autostart module in place of 701 module
  • Off/Auto/Manual selector keyswitch
  • Indicators for
    • Power On
    • Remote start present
    • Charge Fail
    • Common Alarm
    • Fail to start
  • Multi attempt to start programme
  • Programmed timers for
    • Delay on start
    • Mains restoration
    • Run on for engine cooling
    • Crank period
    • Protected Override
ATS

Wall mounted enclosure comprising -

  • 4 Pole changeover contactors (2)
  • Indicators for
    • Mains available
    • Mains on load
    • Generator Available
    • Generator on load
  • Phase failure monitor

(1) 1104C-44TAG1/2 & 1006TAG/TAG2 are fitted with LC electronic governing. 1106C-E66TAG4 has electronic engine management.

(2) Single phase sets are not fitted with a voltmeter selector switch and have switchgear to suit.

(3) Above 250 Amp, the MCCB is supplied fitted in an alternator mounted enclosure separate to the autostart control panel.

 

 

Standard Tempest Specification

Perkins 400, 1000 & 1100 Range ( 200 to 650 KVA )

New Generators - British Made New Generators - Perkins
Generating Set
New Generator Acoustic Set (Canopy) with Perkins Engine
  • Set Mounted Tropical Duty Radiator
  • Engine Driven Cooling Fan with Protection Guard
  • Radiator Stone Guard
  • Fuel, Lubricating Oil and Air Filter(s) with Restriction Indicator(s)
  • Electronic Engine Management System
  • 24 Volt electric start with charging alternator
  • Protection Switches for
    • Low oil pressure
    • High Engine Temprature
    • Low coolant level
  • Wiring to Control Panel
  • Steel base frame with integral 8 hour capacity fuel tank, complete with contents gauge, steel wire braded fuel lines, fill, vent and drain fittings
  • Anti vibration mountings fitted between the engine/alternator feet and base
  • Set mounted Yuasa maintenance free lead acid battery with leads and terminals
  • Exhaust flexible section(s) with connections
  • S.L.S. exhaust Silencer(s) supplied loose
  • Load and function tests
  • Paint finish to our standard scheme
  • Comprehensive user manual
Keystart (Upto 1600 A)

Alternator mounted profile control panel comprising -

  • Ammeter per phase
  • 1 x voltmeter
  • Voltmeter selector switch
  • Dual scale frequency/RPM indicator
  • Hour counter
  • 3 pole MCB/MCCB Mounted in control panel (1)
  • Key Start/Stop switch (701 module fitted to 1300 series)
  • Shutdown indicator for
    • High Engine Temperature
    • Low oil pressure
    • Low coolant level
    • Overspeed
  • Oil Pressure Gauge
  • Water temperature gauge
  • Battery voltmeter
  • Diagnostic socket
Keystart (Above 1600 A)

As above but with ACB mounted in a separate freestanding cubicle

Autostart (Upto 909 A)

As keystart but comprising the following additions -

New Generator Open Set with Perkins Engine

  • Constant Potential barrety charger
  • Battery charger On/Off pushbutton
  • Deep Sea 521K autostart module
  • Off/Auto/Manual selector keyswitch
  • Indicators for
    • Power On
    • Remote start present
    • Charge Fail
    • Common Alarm
    • Fail to start
  • Multi attempt to start programme
  • Programmed timers for
    • Delay on start
    • Mains restoration
    • Run on for engine cooling
    • Crank period
    • Protected Override
  • Diagnostic socket for engines with electronic management
Autostart (Above 909 A without MCCB)

As above but excludng MCCB

ATS (Upto 1000 A)

Wall mounted enclosure comprising -

  • 4 Pole changeover contactors
  • Indicators for
    • Mains available
    • Mains on load
    • Generator Available
    • Generator on load
  • Phase failure monitor
ATS (Above 1000 A)

As above but

  • 1000 A to 1250 A with motor operated MCCN's
  • 1600 and above with motor operated ACB's

(1) Above 250 Amp, the MCCB is supplied fitted in an alternator mounted enclosure separate to the control panel.

Amps are at PRP Rating

 

 

Standard Tempest Specification

Perkins 4000 Range ( 650 to 2000 KVA )

New Generators - British Made New Generators - Perkins
Generating Set
New Generator Open Set with Perkins Engine
  • Set Mounted Tropical Duty Radiator
  • Engine Driven Cooling Fan with Protection Guard
  • Radiator Stone Guard
  • Fuel, Lubricating Oil and Air Filters with Restriction Indicators
  • Electronic governing at 1500/1800 RPM in accordance with BS5514A1
  • 24 Volt electric start with charging alternator
  • Protection Switches for
    • Low oil pressure
    • High Engine Temprature
    • Low coolant level
  • Wiring to Control Panel
  • Open channel baseframe (8 hour capacity basefuel tank with 4006C-23 Models), steel wire braded fuel lines terminated to base
  • Anti vibration mountings supplied loose
  • Set mounted Yuasa maintenance free lead acid battery with leads and terminals
  • Exhaust flexible section(s) with connections
  • S.L.S. exhaust Silencer(s) supplied loose
  • Load and function tests
  • Paint finish to our standard scheme
  • Comprehensive user manual
Keystart (Upto 1600 A)

Alternator mounted profile control panel comprising -

  • Ammeter per phase
  • 1 x voltmeter
  • Voltmeter selector switch
  • Dual scale frequency/RPM indicator
  • Hour counter
  • 3 pole MCB/MCCB in separate alternator mounted cubicle
  • Deep Sea 701 keystart module
  • Shutdown indicator for
    • High Engine Temperature
    • Low oil pressure
    • Low coolant level
    • Overspeed
  • Oil Pressure Gauge
  • Water temperature gauge
  • Battery voltmeter
Keystart (Above 1600 A)

As above but with ACB mounted in a separate freestanding cubicle

Autostart (Without MCCB)

As keystart but comprising the following additions -

New Generator Acoustic (Canopy) Set with Perkins Engine

  • Constant Potential barrety charger
  • Battery charger On/Off pushbutton
  • Deep Sea 521K autostart module in place of 701 module
  • Off/Auto/Manual selector keyswitch
  • Indicators for
    • Power On
    • Remote start present
    • Charge Fail
    • Common Alarm
    • Fail to start
  • Multi attempt to start programme
  • Programmed timers for
    • Delay on start
    • Mains restoration
    • Run on for engine cooling
    • Crank period
    • Protected Override
  • Excluding MCCB
ATS

Wall mounted enclosure comprising -

  • Motor operated MCCB's 1000 A to 1250 A
  • Motor operated ACB's 1600 A and above
  • Indicators for
    • Mains available
    • Mains on load
    • Generator Available
    • Generator on load
  • Phase failure monitor

Amps are at PRP Rating

 

 

DIMENSIONS

Approximate Shipping Specifications

New Generators - British Made New Generators - Perkins
Model CANOPIED OPEN
Length (cm) Width (cm) Height (cm) Weight (kg) Length (cm) Width (cm) Height (cm) Weight (kg)
403C-11G 160 73 118 650 115 56 108 390
403C-15G 160 73 118 730 115 56 117 470
404C-22G 160 73 118 820 132 56 122 560
1103A-33G 181 76 135 1100 147 70 136 800
1103A-33TG1 231 78 141 1350 158 70 136 960
1104A-33TG2 231 78 141 1350 163 70 144 960
1104A-44TG1 277 86 156 1500 180 70 148 960
1104C-44TAG1 277 86 156 1545 186 72 149 1,080
1104C-44TG2 277 86 156 1545 180 70 148 1,080
1006TG1A / 2A - - - - 211 73 149 1,250
1104C-44TAG2 277 86 156 1595 186 72 149 1,130
1006TAG 290 95 190 1830 231 77 158 1,310
1006TAG2 290 95 190 1870 231 77 158 1,350
1006C-E66TAG4 345 115 187 2150 236 79 170 1,590
E87TAG3 345 115 187 2390 254 86 187 1,830
E87TAG4 345 115 187 2480 254 86 187 1,920
E87TAG6 345 115 187 2480 254 86 187 1,920
E14TAG2 400 115 201 4430 318 113 215 3,580
E14TAG3 438 125 222 4550 318 113 215 3,700
E15TAG1 / 2 438 125 222 4900 340 113 222 3,900
E18TAG1 / 2 438 165 222 tba 340 154 227 4,700
23TAG2A / 3A 810 210 300 tba 397 171 232 6,350
4008-TAG2A Refer to Sales 465 205 227 7,500
4012-46TWG2A 473 178 245 8,900
4012-46TWG3A 473 198 245 9,000
4012-46TAG1A 499 219 251 9,740
4012-46TAG2A 499 219 251 10,000
4012-46TAG3A 510 216 281 10,600
All dimensions and weights are approximate and should not be used for installation
Canopy height includes silencer